- This topic has 4 replies, 3 voices, and was last updated 10 years, 6 months ago by .
Viewing 5 posts - 1 through 5 (of 5 total)
Viewing 5 posts - 1 through 5 (of 5 total)
- You must be logged in to reply to this topic.
OpenSprinkler › Forums › Hardware Questions › OpenSprinkler › Vopltage to all stations at same time
Have a Opensprinkler V 2.1.6 with extra 8 station extender.
When powering up open sprinkler to , lets say , station 1 I get 21.6 VAC output at the the Station ! output BUT at the same time I get 6.3 VAC at ALL the other station outputs at the same time. This 6.3 VAC is enough to activate all 16 led warning lights at the same time on my control board.
Is this 6.3 VAC output at all stations normal ??????????
It’s normal to see such stray voltage — when the triac is turned off, its drain (or more precisely MT1) pin floats and can easily pick up stray voltage. It’s typically not sufficient to power anything substantial though. Are you seeing all LED lights turning on? How large is the current limiting resistor for each LED?
Thanks Ray. Problem turned out to be a couple of bad solder joints on my own wiring shorting out the 2 stations .
Next Problem.
I cannot seem to program the unit to operate any more than one station at the same time.
I have a 16 output which I wish to use to program during a 24 hour period, which means that some stations will be operating at the same point in time.
For example:
sTation 1 start 9.30 am and run for 6 hours
station 4 start 10.20 am and run for 4 hours
station 12 start 1.00 pm and run for 50 minutes
station 8 start 1.30 pm and run for 10 minutes.
I can only get the unit to activate sequentially.That is Station 1 must complete its 6 hours before station 4 starts. This means that station 4 starts at 3.30
and the others cannot run until each station is finished.
How can I set the program up to do what I want it to do?
Thanks
Gerry
Hi!
I think ist the same Problem like in th post from me:
https://opensprinkler.com/forums/topic/program-start-sequentiel/
Thanks Michael. That was my answer. Everything OK now.
Thanks all appreciate the help